Yokogawa FVX110 Bedienungsanleitung Seite 19

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 164
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 18
<2. Handling Cautions>
2-9
IM 01S01C01-01EN
Electrical Data:
Rating 1 (Entity)
For Groups A, B, C, D, E, F, and G or Group
IIC
Ui (vmax) = 24 V dc
Ii (Imax) = 250 mA
Pi (Pmax) = 1.2 W
Ci = 1.76 nF
Li = 0 mH
or
Rating 2 (FISCO)
For Groups A, B, C, D, E, F, and G or Group
IIC
Ui (vmax) = 17.5 V dc
Ii (Imax) = 500 mA
Pi (Pmax) = 5.5 W
Ci = 1.76 nF
Li = 0 mH
or
Rating 3 (FISCO)
For Groups C, D, E, F, and G or Group IIB
Ui (vmax) = 17.5 V dc
Ii (Imax) = 500 mA
Pi (Pmax) = 5.5 W
Ci = 1.76 nF
Li = 0 mH
Installation requirements;
Po Pi Uo Ui Io Ii,
Co Ci + Ccable Lo Li + Lcable
Vmax Voc Imax Isc
Ca Ci + Ccable La Li + Lcable
Uo, Io, Po, Co, Lo,Voc, Isc, Ca and La are
parameters of barrier.
Caution for CSA Non-incendive type.
(Following contents refer to “DOC. No.
ICS018”)
Installation Diagram for Non-incendive
or Type of protection "n" (Division 2
Installation)
Non-Hazardous Location
Hazardous Location
F0208.ai
Terminator
CSA Certified
Equipment [nL]
Terminator
+
Field Instruments
+
+
+
+
Indicator
Field Instruments
Note 1. Installation should be in accordance with
Canadian Electrical Code Part I and local
Electrical Code.
Note 2. Dust-tight conduit seal must be used when
installed in class II and III environments.
Note 3. Do not alter drawing without authorization
from CSA.
Electrical Data:
Rating (including FNICO)
Ui or Vmax = 32 V
Ci = 1.76 nF
Li = 0 mH
Seitenansicht 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 163 164

Kommentare zu diesen Handbüchern

Keine Kommentare