<3. INSTALLATION>
3-6
IM 01E25D11-01EN
Mounting Procedure (with optional
Grounding Rings GR1 for sizes up to
1000 mm (40 in.)):
1. Handles of the grounding ring have some
holes which correspond to outer diameter
of each ange type. There are printings
near each hole. The printings show types
of ange. See the table below.
Printing
Process
Connection Code
Flange Standard
ASME -CA1
ASME B16.5
Class 150, ASME
B16.47 Class 150
AWWA -CB1
AWWA C207
Class D
PN10 -CE1 EN1092-1 PN10
PN16 -CE2 EN1092-1 PN16
10K -CJ1 JIS B2220 10K
AS -CS1, -CS2, -CT1
AS2129 table D, E
AS4087 PN16
F12 -CG1 JIS F12 (JIS 75M)
2. Conrm the centering pin is xed to the
hole corresponding to ange or x the
centering pin to the correct hole.
3. Hang the grounding rings with their
ange type printings outer side of the
owtube. Set the angle of both handles
symmetrically to be 45 degree from top. If
there are any bolt-holes under the handles,
turn the grounding rings clockwise in order
to locate handles between bolt-holes.
Center the grounding ring to the center of
the owtube.
4. Connect the wire from the grounding ring
to the screw of the owtube’s ange and x
the wire by the nut. This procedure (item 1
to 4) must be done for the both sides of the
owtube.
5. Install the owtube into the customer’s pipe
with the gaskets A.
F0313.ai
Handle
Screw & Nut : Connect the wire from the
grounding ring or the customer’s pipe
Clockwise
Gasket B
Grounding Ring
Handle
Printed
Surface
Hole
Printing of
Flange Type
Flowtube
Centering Pin
Centering Pin
F12
10K
Note : Gasket A and B are also placed concentrically with
the owtube.
Figure 3.3.5 Mounting Procedure with Grounding
Rings GR1 for sizes up to 1000 mm
(40 in.)
Mounting Procedure (with optional
Grounding Rings GR1 for sizes 1100mm (44
in.)) and above :
1. The grounding ring is temporarilyxed
onto the owtube by four bolts. Hang the
grounding ring up using a crane or a hoist
so that it would not fall down from the
owtube while setting the gasket B.
2. Unfasten the bolts and remove the
grounding ring off from theowtube.
3. Place the gasket B to the owtube. Cut out
holes on the gasket B if necessary, so that
the bolts can go through. Fix the grounding
ring to the owtube by the four bolts again.
4. Connect the wire from the grounding ring
to the screw at the owtubeange and x
the wire by the nut. This procedure (item 1
to 4) must be done for the both sides of the
owtube.