
App-1
IM 04L21B01-17EN
Appendix
App
Appendix 1 Data Dropout during Modbus
Communication
Data Dropout during Modbus Client
If the response to the previous command is not complete when the FX attempts to
issue a command to a server device, the FX cannot issue the command causing a data
dropout. Take appropriate measures by referring to the following figures.
Read cycle
Data dropout
(Servers 2 and 3)
Data dropout
(Server 3)
Server device 1
Server device 2
Server device 3
G
G
G
G
G
G
Read cycle
(Retry)
: Status lamp
: Response from the server device
: Command from the FX
Data dropout
(Servers 2 and 3)
Server device 1
Server device 2
Server device 3
Read cycle
Timeout value
Connection dropped
Data dropout
(Servers 2 and 3)
Server device 1
Server device 2
Server device 3
G
G
G
G
G
G
G
O
Connection dropped Connection recovered
Timeout value
G
G
G
G
O
Y
Connection retry time
1
G G
G GG
G
Y
O R
1. When the response from the server device takes a long time
2. When the connection is dropped because there is no response from the server device
3. When the communication recovers by connection retry
1: The first connection retry after the connection is
dropped is shorter than the specified interval.
The status lamp condition is an example when
connection retry is configured.
Appendix
Kommentare zu diesen Handbüchern