Yokogawa Button Operated MV2000 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Sensoren Yokogawa Button Operated MV2000 herunter. Yokogawa Button Operated MV2000 User Manual [en] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1

User’sManualModels MV1004/MV1006/MV1008/MV1012/MV1024MV1000First Step GuideIM MV1000-02E2nd Edition

Seite 2 - User Registration

Checking the Contents of the PackageUnpack the box and check the contents before operating the instrument. If some of the contents are not correct or

Seite 3 - Contents

MODEL and SUFFIX CodeModel code Suffix code DescriptionMV1004 4 channel, 125 ms (fast sampling mode: 25 ms)MV1006 6 channel, 1 s (fast sampling mode:

Seite 4

Standard AccessoriesThe standard accessories below are supplied with the instrument. Check that all contents are present and undamaged.No. Name Part N

Seite 5 - Revisions

Optional Accessories (Sold Separately)The following optional accessories are available for purchase separately. If you ordered any optional accessorie

Seite 6 - Safety Precautions

How to Use This ManualConventions Used in This Manual• This user’s manual assumes that the display language is set to English (language suffix code -

Seite 7

Names of PartsFrontWith the cover openLCDTrend display and all other operation and configuration screens are displayed here.Power indicatorGlows red w

Seite 8

Basic OperationPanel Keys LCD screenKeysSoft keysSelect menu items displayed at the bottom of the screen.START/STOP keyStarts or stops memory sampling

Seite 9 - Protection of Environment

Entering Values and CharactersThe character/number input window and DISP/ENTER key are used to set the date/time, set the display span of the input ra

Seite 10 - IM MV1000-02E

Memo18IM MV1000-02E

Seite 11 - MODEL and SUFFIX Code

MV1000 WorkflowTo set up the MV for quick use in the field, follow these steps: InstallConnect CablesTurn ONSet Measurement RangeInsert CF cardSet D

Seite 12 - Standard Accessories

PRS 105-02EUser RegistrationThank you for purchasing YOKOGAWA products.We invite you to register your products in order to receive the most up to date

Seite 13

InstallationLocationInstall the MV indoors in an environment that meets the following conditions:• Temperature of 0 to 40°C Install the MV in a loca

Seite 14 - How to Use This Manual

InstallationInstall the MV on a flat surface. NoteYou cannot put the MV in a stack.• Using the stand When using the stand, push it out until it

Seite 15 - Names of Parts

Connecting Input CablesWiring to the Signal Input Terminals WARNING• To prevent electric shock, make sure that the power source is turned OFF.CAUTIO

Seite 16 - Basic Operation

Connecting the input wires in parallel with other devices can cause signal degradation, affecting all connected devices. If you have to make a paralle

Seite 17 - Entering Numeric Values

+/A/bCH1CH2CH3CH4CH1CH2CH3CH4CH5CH6–/B+/A/b–/BCH5 CH3 CH1CH6 CH4 CH2CH3 CH1CH4 CH2/b+/A–/B/b+/A–/BScrew TerminalMV1004 input terminal blockMV1008 inpu

Seite 18

Wiring Clamped TerminalsRemove the terminal block.Hold both ends of the terminal block and pull straight.Input signal wireFirst, loosen the screw at t

Seite 19 - MV1000 Workflow

Connecting a Power CableConnecting the Power Cord (if the power supply voltage suffix code is -1)Precautions to Be Taken While Connecting the Power Su

Seite 20 - Installation

Connecting the Power Cord (if the power supply voltage suffix code is -2)When Using an AC AdapterPrecautions to Be Taken While Connecting the Power Su

Seite 21

When Using a DC Power SupplyPrecautions to Be Taken While Connecting the Power SupplyMake sure to follow the warnings below when connecting the power

Seite 22 - Connecting Input Cables

Connecting the AC Adapter (if the power supply voltage suffix code is -3)Before Connecting the Power SupplyTo prevent the possibility of electric shoc

Seite 23 - Wiring Procedure

ContentsSafety Precautions ...

Seite 24 - Wiring Screw Terminals

Functional GroundingWhen using the AC adapter, connecting the functional grounding terminal of the instrument to earth ground reduce noise. Use the fu

Seite 25 - Wiring Clamped Terminals

Turning the Power ON/OFFTurning the Power ON CAUTIONBefore turning ON the power switch, check that• The power cord/wires are connected correctly to

Seite 26 - Connecting a Power Cable

Quick SettingsUsing the quick settings function, you can switch quickly to the measurement channel (measurement range and alarm) and data save configu

Seite 27 - WARNING

Press T/DIVChange the display-data save settings1. Select the Trend/Storage interval. Press the 1min soft key.2. Select the Save interval. Press the

Seite 28

MeasurementInserting the CF Card1. Open the cover. CF card“This side up” facing upThis side upCAUTION2. Insert the CF card into the slot.

Seite 29

Starting the Memory Sample1. Press START/STOP once.Memory sampling starts, and the key blinks green. START/STOP keyMemory sampling progressDISP

Seite 30 - Charging the Ni-MH Battery

Removing the CF Card1. Press FUNC once.2. Press Media eject once. Displays the CF card icon3. Press the CF soft key once. The message “Medi

Seite 31 - CAUTION

Default MV1000 SettingsThe setting mode and basic setting mode settings and their default values are listed in this section.Setting Mode Menu• Menu

Seite 32 - Quick Settings

• Menu Page 50 Page 51Page 51 Page 511Pages 51 and 521 Page 512Page 52 Pages 53 to 56Page 562 Page 57Page 571 The function will be dis

Seite 33 - Press T/DIV

Setting Mode Settings and Default ValuesMenu TabMeas channel > Range, AlarmSetting Selectable Range or Choices Default ValueFirst-CH, Last-CH Numer

Seite 34 - Measurement

MV1000/MV2000 User’s Manual (Electronic Manual Provided on the Accompanying CD)Chapter 1 Feature OverviewChapter 2 Installation and WiringChapter 3

Seite 35 - Stopping the Memory Sample

Setting Selectable Range or Choices Default ValueType H/L/h/l/R/r/T/t HValue Numeric value 0.000Relay On/Off OffNo. I01 to I06, S01 to S30 I01Detect O

Seite 36 - Viewing Data with DAQSTANDARD

Meas channel > Alarm markSetting Selectable Range or Choices Default ValueFirst-CH, Last-CH Numeric value (channel number) 1 to 24 1Mark kind Alarm

Seite 37 - Default MV1000 Settings

Math channel > TLOG, Rolling averageSetting Selectable Range or Choices Default ValueFirst-CH, Last-CH Numeric value (computation channel number) 1

Seite 38 - • Initialize

Math channel > Color scale bandSetting Selectable Range or Choices Default ValueFirst-CH, Last-CH Numeric value (computation channel number) 101 to

Seite 39 - Menu Tab

Display > TrendSetting Selectable Range or Choices Default ValueDirection Horizontal/Vertical/Wide/Split WideTrend clear On/Off OnMessage direction

Seite 40

MessageSetting Selectable Range or Choices Default ValueMessage No. 1–10/11–20/21–30/31–40/41–50/51–60/61–70/71–80/81–90/91–1001–10Characters Characte

Seite 41

Timer, Event action > Event actionSetting Selectable Range or Choices Default ValueLogic box number 1/2/3/4/.../39/40 1Event None/Remote/Relay/Swit

Seite 42

Menu customize > Function menuSetting ChoicesPause Display Select/HideMessageFree messageMedia ejectSnap shotManual sampleAlarmACKLCD SaverTriggerS

Seite 43

Setting Sub Menu ChoicesINFORMATION ALARM SUMMARY Select/HideMESSAGE SUMMARYMEMORY SUMMARYMODBUS CLIENTMODBUS MASTERRELAYREPORT DATACOLUMN BARTO HISTO

Seite 44

Basic Setting Mode Settings and Default ValuesEnvironment TabOperating environmentSetting Selectable Range or Choices Default ValueOperating environme

Seite 45

Thank you for purchasing the MV 1000 (hereafter referred to as the MV). This manual explains the minimum steps required to start measuring quickly. It

Seite 46

Communication > POP3 DetailsSetting Selectable Range or Choices Default ValuePOP3 DetailsSend delay [second] 0 to 10 s 2POP3 Login PLAIN/APOP PLAIN

Seite 47

A/D, MemorySetting Selectable Range or Choices Default ValueScan interval > Scan mode Normal/Fast NormalNormal > Scan interval 125ms/250ms (MV10

Seite 48 - Basic setting mode

Login > User settingsSetting Selectable Range or Choices Default ValueUser number 1/2/3/…/29/30 1Mode Off/Key/Comm/Web/Key+Comm OffUser name Charac

Seite 49 - Environment Tab

Communication (Ethernet) > IP-addressSetting Selectable Range or Choices Default ValueIP-addressDHCP Use/Not NotDNS accession Use/Not UseHost-name

Seite 50

Communication (Ethernet) > E-Mail > Basic settingsSetting Selectable Range or Choices Default ValueBasic settingsSMTP server name Character stri

Seite 51

Communication (Ethernet) > E-Mail > System settingsSetting Selectable Range or Choices Default ValueSystem settingsRecipient 1 On/Off OffRecipie

Seite 52

Communication (Ethernet) > Modbus client > Modbus server settingsSetting Selectable Range or Choices Default ValueServer number 1-8/9-16 1-8Port

Seite 53

Status relaySetting Selectable Range or Choices Default ValueStatus relayMemory/Media status On/Off OffMeasurement error On/Off OffCommunication error

Seite 54

Safety Precautions• This instrument conforms to IEC safety class I (provided with terminal for protective grounding), Installation Category II, and E

Seite 55

WARNING• Use the Correct Power Supply Ensure that the source voltage matches the voltage of the power supply before turning the power ON.• Use the

Seite 56

• Do not use the battery box if abnormal symptoms are present such as leakage, deformity, and discoloration.• Do not carry the battery box along with

Seite 57 - Initialize Tab

CF Card Handling Precautions• The CF card is delicate and should be handled with caution.• Write operations to the CF card may fail if it is operate

Verwandte Modelle: Button Operated MV1000

Kommentare zu diesen Handbüchern

Keine Kommentare