5-1
IM 01R04B04-00E-E 8th edition March 01, 2011 -00
All Rights Reserved. Copyright © 2003, Rota Yokogawa
Data setting can be done by HART-Communication (see chapter 6) or with the 3 keys on the front panel.
The following section describes how to use the three panel keys.
Operate the display unit under the condition where direct sunlight, etc.... do not shine to the setting
switches directly when the parameter setting operation is carried out.
(1) Always use the setting switches with the cover of the ROTAMASS closed.
(2) Use these switches when covered by the glass window.
(3) If dirt, dust or other substances surfaces on the display panel glass, wipe them clean with a soft dry cloth.
(4) The operation with dirty gloves may cause a switch response error.
Construction of ROTAMASS display :
LCD dot matrix (32 x 132 dots)
• 1 line indication or
• 2 line indication or
• 3 line indication or
• 4 line indication
3 infrared switches
,
,
: conrm data setting
or entry data setting
or conrm parameter
: move cursor right to
next position
+
: return to higher menu level
: move to lower
parameter
or increment value
+ : move to upper
parameter
General display indication :
123.450
kg/h
MFR
Indication of title
Indication of numeric value
Indication of unit
F52.EPS
Lock symbol for indication of hardware write protect