Yokogawa JUXTA VJ Series Limit Alarms Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Sensoren Yokogawa JUXTA VJ Series Limit Alarms herunter. Yokogawa JUXTA VJ Series Limit Alarms User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Communication Functions

User’sManualIM 77J01J11-01EVJ SeriesCommunication FunctionsIM 77J01J11-01E3rd Edition

Seite 2

1-2<Toc> <Ind> <1. Setup >IM 77J01J11-01E1.2 Notes on Setting ParametersThis section describes the setting parameters for using the

Seite 3 - Introduction

<Toc> <Ind> <1. Setup >1-3IM 77J01J11-01E● Address number (ADDRESS)Set the address number of the VJ Series itself. An address numb

Seite 5 - Modification

<Toc> <Ind> <2. Communication Specifications >2-1IM 77J01J11-01E2. Communication SpecificationsThe RS-485 communication interface h

Seite 7 - CONTENTS

<Toc> <Ind> <3. PC Link Communication >3-1IM 77J01J11-01E3. PC Link Communication3.1 OverviewThe use of PC link communication enabl

Seite 8

3-2<Toc> <Ind> <3. PC Link Communication >IM 77J01J11-01E3.1.1 Configuration of CommandCommands sent from a higher-level device to

Seite 9 - 1. Setup

<Toc> <Ind> <3. PC Link Communication >3-3IM 77J01J11-01E3.1.2 Configuration of ResponseResponses from the VJ Series with respect t

Seite 10 - IM 77J01J11-01E

3-4<Toc> <Ind> <3. PC Link Communication >IM 77J01J11-01E3.1.3 Response Error CodesSee Also3.1.2, “Configuration of Response”, for

Seite 11 - ● Data length (DATA LEN)

<Toc> <Ind> <3. PC Link Communication >3-5IM 77J01J11-01E3.2 Commands3.2.1 List of CommandsThe following shows lists of commands av

Seite 13

3-6<Toc> <Ind> <3. PC Link Communication >IM 77J01J11-01E3.2.2 BRD Reading I Relays on a Bit-by-bit Basis● FunctionReads a sequenc

Seite 14

<Toc> <Ind> <3. PC Link Communication >3-7IM 77J01J11-01E3.2.3 BRR Reading I Relays on a Bit-by-bit Basis in a RandomOrder● Functi

Seite 15 - 3. PC Link Communication

3-8<Toc> <Ind> <3. PC Link Communication >IM 77J01J11-01E3.2.4 BRS Specifying I Relays to be Monitored on a Bit-by-bitBasis● Funct

Seite 16

<Toc> <Ind> <3. PC Link Communication >3-9IM 77J01J11-01E3.2.5 BRM Monitoring I Relays on a Bit-by-bit Basis● FunctionReads the ON

Seite 17

3-10<Toc> <Ind> <3. PC Link Communication >IM 77J01J11-01E3.2.6 WRD Reading D Registers/I Relays on a Word-by-wordBasis● FunctionR

Seite 18 - 030230E.EPS

<Toc> <Ind> <3. PC Link Communication >3-11IM 77J01J11-01E3.2.7 WRR Reading D Registers/I Relays on a Word-by-wordBasis in a Rando

Seite 19 - 030203E.EPS

3-12<Toc> <Ind> <3. PC Link Communication >IM 77J01J11-01E3.2.8 WRS Specifying D Registers/I Relays to be Monitored on aWord-by-wo

Seite 20 - ● Example:

<Toc> <Ind> <3. PC Link Communication >3-13IM 77J01J11-01E3.2.9 WRM Monitoring D Registers/I Relays on a Word-by-wordBasis● Functi

Seite 21

3-14<Toc> <Ind> <3. PC Link Communication >IM 77J01J11-01E3.2.10 INF Reading the Model, Presence/Absence of Options, andRevision●

Seite 22 - 030212E.EPS

<Toc> <Ind> <3. PC Link Communication >3-15IM 77J01J11-01E3.3 Communication with Higher-level DevicesHigher-level devices are those

Seite 23

<Toc> <Ind> <Rev>iIM 77J01J11-01E 3rd Edition : Oct. 15, 2007-00IntroductionThis instruction manual describes the communication func

Seite 24

3-16<Toc> <Ind> <3. PC Link Communication >IM 77J01J11-01E3.3.1 Example of Communication Program Created Using VisualBasicThis subs

Seite 25 - (output is 50.0 %)

<Toc> <Ind> <3. PC Link Communication >3-17IM 77J01J11-01ELabel1.Caption = "[stx]" + strSend + "[etx][cr]"Label

Seite 26 - Word-by-word Basis

3-18<Toc> <Ind> <3. PC Link Communication >IM 77J01J11-01E'Initialize label control that displays character strings sent and r

Seite 27 - CPU number: 01

<Toc> <Ind> <3. PC Link Communication >3-19IM 77J01J11-01EstrReceive = "Time Out!"fSend = False 'Receiving is regard

Seite 28 - Revision

3-20<Toc> <Ind> <3. PC Link Communication >IM 77J01J11-01E3.3.2 Communication with UT Link ModuleCommunication with FA-M3 is achiev

Seite 29

<Toc> <Ind> <3. PC Link Communication >3-21IM 77J01J11-01E3.3.3 Communication with Graphic PanelCommunication with a graphic panel

Seite 30

Blank Page

Seite 31

<Toc> <Ind> <4. Ladder Communication >4-1IM 77J01J11-01E4. Ladder Communication4.1 OverviewCommunication with a sequencer (PLC) is

Seite 32

4-2<Toc> <Ind> <4. Ladder Communication >IM 77J01J11-01E4.2 Commands/Responses at the PLCThe PLC sends commands and receives respon

Seite 33

<Toc> <Ind> <4. Ladder Communication >4-3IM 77J01J11-01E4.2.2 Reading ParametersParameters from the PLC are read in the VJ Series s

Seite 34

ii<Toc> <Ind> <Rev>IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-00Documentation Conventions SymbolsThis manual uses the following sy

Seite 35 - Graphic panel

4-4<Toc> <Ind> <4. Ladder Communication >IM 77J01J11-01E4.2.3 Response Error CodesData that the master station (PLC) will receive i

Seite 36

<Toc> <Ind> <5. MODBUS Communication >5-1IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-005. MODBUS Communication5.1 OverviewThe use o

Seite 37 - 4. Ladder Communication

5-2<Toc> <Ind> <5. MODBUS Communication >IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-005.1.1 Configuration of MessageMessages sent

Seite 38

<Toc> <Ind> <5. MODBUS Communication >5-3IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-005.1.2 Specifying D RegistersSpecification of

Seite 39 - 4.2.2 Reading Parameters

5-4<Toc> <Ind> <5. MODBUS Communication >IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-005.2 Function Codes5.2.1 List of Function Cod

Seite 40 - 4.2.3 Response Error Codes

<Toc> <Ind> <5. MODBUS Communication >5-5IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-0003 Reads data from multiple D registers.● Fu

Seite 41 - 5. MODBUS Communication

5-6<Toc> <Ind> <5. MODBUS Communication >IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-00● Example:Reading the statuses of alarms-1 a

Seite 42 - 050103E.EPS

<Toc> <Ind> <5. MODBUS Communication >5-7IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-0008 Performs a loop back test.● FunctionThis

Seite 43 - 5.1.2 Specifying D Registers

5-8<Toc> <Ind> <5. MODBUS Communication >IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-005.2.2 Response Error Code[Response]● Message

Seite 44 - 5.2 Function Codes

<Toc> <Ind> <5. MODBUS Communication >5-9IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-005.3 Example of Setting up Commercially Avail

Seite 45 - 050205E.EPS

<Toc> <Ind> <Rev>iiiIM 77J01J11-01E 3rd Edition : Oct. 15, 2007-00Notices Regarding This Instruction Manual(1) This manual should b

Seite 46 - : 01030400010000F7[CR][LF]

5-10<Toc> <Ind> <5. MODBUS Communication >IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-00● Example of setting the tag variable of In

Seite 47 - 050216E.EPS

<Toc> <Ind> <6. Functions and Usage of D Registers >6-1IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-006. Functions and Usage of D Re

Seite 48 - ● Response Error Codes

6-2<Toc> <Ind> <6. Functions and Usage of D Registers >IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-006.3 D Register Map TableD-Regi

Seite 49 - SCADA Software

<Toc> <Ind> <6. Functions and Usage of D Registers >6-3IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-006.3.1 Contents of D Registers●

Seite 50 - 050302J.EPS

6-4<Toc> <Ind> <6. Functions and Usage of D Registers >IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-00● D0002, D0003: INPUT1_L, INPU

Seite 51 - 6.1 Overview of D Registers

<Toc> <Ind> <7. Functions and Usage of I Relays >7-1IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-007. Functions and Usage of I Relay

Seite 52 - 6.3 D Register Map Table

7-2<Toc> <Ind> <7. Functions and Usage of I Relays >IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-007.1 StatusThe following table sho

Seite 53 - 6.3.1 Contents of D Registers

<Toc> <Ind> <Appendix. Table of ASCII Codes (Alphanumeric Codes) >App.-1IM 77J01J11-01EAppendix Table of ASCII Codes(Alphanumeric C

Seite 55 - PC link communication

i<Int> <Toc> <Ind>IM 77J01J11-01ERevision Information● Title : VJ Series Communication Functions● Manual No. : IM77J01J11-01EAug. 19

Seite 56 - 7.1 Status

iv<Toc> <Ind> <Rev>IM 77J01J11-01E 3rd Edition : Oct. 15, 2007-00 Force Majeure(1) Yokogawa does not make any warranties regarding

Seite 58

Toc-1<Int> <Ind> <Rev>IM 77J01J11-01ECONTENTSIM 77J01J11-01E 3rd EditionVJ Series Communication FunctionsIntroduction...

Seite 59 - Revision Information

<Int> <Ind> <Rev>IM 77J01J11-01EToc-24. Ladder Communication......

Seite 60

<Toc> <Ind> <1. Setup >1-1IM 77J01J11-01E1. SetupThis chapter describes the setup procedure required to use the communicationfuncti

Kommentare zu diesen Handbüchern

Keine Kommentare