2.4 Connecting Signal Wires
Attaching and Removing the Terminal Block
The I/O terminals of the modules in the figure below can be removed. The terminals
of the 30-CH, Medium-Speed DCV/TC/DI Input Module (MX110-VTD-L30) cannot be
removed.
The terminal cover can be removed by pressing backward with the cover lifted up.
4-CH, High-Speed Universal
Input Module
The terminal block can
be attached and
detached.
4-CH, Medium-Speed Strain
Input Module (-B12, -B35)
Pull-out
handle
The terminal plate can be
attached and detached.
Attachment screw
(Loosen before removing the terminal plate.)
10-CH, Medium-Speed Universal Input Module/
6-CH, Medium-Speed 4-wire RTD Resistance
Input Module/
10-CH, Pulse Input Module/
10-CH, High-Speed Digital Input Module
(-D05, -D24)
8-CH, Medium-Speed Analog
Output Module/
8-CH, PWM Output Module/
10-CH, Medium-Speed Digital
Output Module
The terminal plate can be
attached and detached.
Attachment screw
(Loosen before removing the terminal plate.)
Pull-out
handle
The terminal block can be
attached and detached.
Attachment screw
(Loosen before removing the terminal block)