Yokogawa JUXTA VJCE Bedienungsanleitung Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 10
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
10
All Rights Reserved. Copyright © 1999, Yokogawa M&C Corporation IM 77J01C51-01E 2nd Edition July 23,2004-00
5.2 Assignment of Power Supply Terminals
1
1
2
3
2 3
Terminal Number Signal Symbol
SUPPLY L()
SUPPLY N()
GND
CAUTION
Ensure that the power supply voltage for VJCE-01A matches that for the signal conditioner to be
mounted on VJCE-01A. Supply of different power supply voltage may damage VJCE-01A and signal
conditioners.
6. CALIBRATION
Refer to the Users Manual of respective signal conditioner for how to calibrate and for the equipment required for
calibration.
6.1 Items to Check before Power on
Supply power rating is 12 to 36 V DC or 85 to 264 V AC / DC.
Wiring of signal cables
Installation, ambient temperature, humidity, dust, vibration
Please power on after checking the above items.
The VJCE would be in operational status upon power on. However, 10 to 15 minutes are required to satisfy its speci-
fications and performance
6.2 Connection of Calibration Equipment
When Output- or Output-2 is connector, prepare KS2 cable and TE-16 terminal block.
KS2 cable
43
Cable with 16 pairs shield
t=15
80
[VJCE side]
40 pin connector 40 pin connector
[Input/output card side]
Ground terminal
TE-16 Terminal Block
1A 2A 3A 4A 5A 6A 7A 8A
1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 11B 12B 13B 14B 15B 16B
SHLD
9A 10A 11A 12A 13A 14A 15A 16A
SHLD
Seitenansicht 9